This table summarizes the available grades for Interface Concept products.
For details, Please always refer to the User's Manual of the concerned product.


Criterion Standard Extended Rugged Conduction Cooled
Coating Optional Yes Yes Yes
Operat. Temp. 0 to 55°C -20 to 65°C -40 to 75°C or 85°C (*) -40 to 75°C or 85°C at the thermal interface (*)
Rec. airflow 1 .. 2 m/s 2 .. 3 m/s 2 .. 5 m/s -
Oper. HR% no cond. 5 to 90% 5 to 95% 5 to 95% 5 to 95%
Storage Temp. -45 to 85°C -45 to 85°C -45 to 100°C -45 to 100°C
Sinusoidal Vibr 2G
[20..2000]Hz
2G
[20..2000]Hz
5G
[20..2000]Hz
5G
[20..2000]Hz
Random Vibr 0.002g2 /Hz
[10..2000]Hz
0.002g2 /Hz
[10..2000]Hz
0.05g2 /Hz
[10..2000]Hz
0.1g2 /Hz
[10..2000]Hz
Shock 1/2 Sin. 11ms 20G 20G 40G 40G
(*) : For Some architectures, subject to limitation (or extension) depending on Frequency restriction / Processing usage rate. Consult us for more information